Nick Mathewson authored
It seems that 64-bit Sparc Solaris demands 64-bit-aligned access to uint64_t, but does not 64-bit-align the stack-allocated char array we use for cpuworker tags. So this patch adds a set/get_uint64 pair, and uses them to access the conn_id field in the tag. svn:r18743
9f8d095e