Changes
Page history
port drbd pager playbook to prometheus
authored
Oct 15, 2024
by
anarcat
Show whitespace changes
Inline
Side-by-side
howto/drbd.md
View page @
f4eb7fa4
...
...
@@ -114,14 +114,13 @@ Then that device map can be removed with:
### Resyncing disks
In Nagios, if you see this warning
:
A
`DRBDDegraded`
alert looks like this
:
DRBD
CRITICAL: Device 10 WFConnection UpToDate, Device 9 WFConnection UpToDate
DRBD
has 1 out of date disks on fsn-node-04.torproject.org
It means that, on that host (in
my
case
it was
It means that, on that host (in
this
case
`fsn-node-04.torproject.org`
), disks are desynchronized for some
reason. In this case, those are disks 9 and 10. You can confirm that
on the host:
reason. You can confirm that on the host:
# ssh fsn-node-04.torproject.org cat /proc/drbd
[...]
...
...
@@ -132,7 +131,8 @@ on the host:
[...]
You need to find which instance this disk is associated with (see also
above):
above), by asking the Ganeti master for the DRBD disk listing with
`gnt-node list-drbd $NODE`
:
$ ssh fsn-node-01.torproject.org gnt-node list-drbd fsn-node-04
[...]
...
...
...
...