......@@ -46,7 +46,7 @@ upstream RPM by Alien) installs it in a strange location:
This will confirm you are using hardware raid:
root@moly:/home/anarcat# lspci | grep -i raid
root@moly:/home/anarcat# lspci | grep -i megaraid
05:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2108 [Liberator] (rev 05)
This will show the RAID levels of each enclosure, for example this is
......@@ -55,6 +55,11 @@ RAID-10:
root@moly:/home/anarcat# megacli -LdPdInfo -aALL | grep "RAID Level"
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
This is an example of a simple RAID-1 setup:
root@chi-node-04:~# megacli -LdPdInfo -aALL | grep "RAID Level"
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
This lists a summary of all the disks, for example the first disk has
failed here:
......@@ -92,6 +97,57 @@ This will make the drive blink (slot number 0 in enclosure 252):
megacli -PdLocate -start -physdrv[252:0] -aALL
Take the disk offline:
megacli -PDOffline -PhysDrv '[252:0]' -a0
Mark the disk as missing:
megacli -PDMarkMissing -PhysDrv '[252:0]' -a0
Prepare the disk for removal:
megacli -PDPrpRmv -PhysDrv '[252:0]' -a0
Reboot the machine, replace the disk, then inspect status again, you
may see "Unconfigured(good)" as a status:
root@moly:~# megacli -PDList -aALL | grep -e '^Enclosure Device' -e '^Slot' -e '^Firmware'
Enclosure Device ID: 252
Slot Number: 0
Firmware state: Unconfigured(good), Spun Up
[...]
Then you need to re-add the disk to the array:
megacli -PdReplaceMissing -PhysDrv[252:0] -Array0 -row0 -a0
megacli -PDRbld -Start -PhysDrv[252:0] -a0
Example output:
root@moly:~# megacli -PdReplaceMissing -PhysDrv[252:0] -Array0 -row0 -a0
Adapter: 0: Missing PD at Array 0, Row 0 is replaced.
Exit Code: 0x00
root@moly:~# megacli -PDRbld -Start -PhysDrv[252:0] -a0
Started rebuild progress on device(Encl-252 Slot-0)
Exit Code: 0x00
Then the rebuild should have started:
root@moly:~# megacli -PDList -aALL | grep -e '^Enclosure Device' -e '^Slot' -e '^Firmware'
Enclosure Device ID: 252
Slot Number: 0
Firmware state: Rebuild
[...]
To follow progress:
watch /opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -ShowProg -PhysDrv[252:0] -a0
## SMART monitoring
Some servers will fail to properly detect disk drives in their SMART
......